Traitement de l’air comprimé

Quality air is the guarantee of a healthy and controlled industrial process. Thus, for more than 30 years, we have been using our know-how for the sustainability of your industry by offering you filtration and drying solutions adapted to the most demanding needs.

Low pressure (<16 bar) thermal mass refrigeration air dryers

30 m³/h (0,5 m3/min)  > 3160 m³/h (52,6 m3/min)
Low pressure (<16 bar) thermal mass refrigeration air dryers

Our MASTERIA dryer range uses the principe of thermal mass refrigeration in order to efficiently dry the compressed air produced upstream in the network. Thanks to its efficient refrigeration system and our patented 3-in1 exchanger, the compressed air is dried by means of an optimal exchange in contraflow over the entire contact surface.

The CTA thermal mass dryers are equipped with the latest generation DTM (DUAL TRANSFER MODE) exchanger, which ensures optimal heat transfer cools the humid air saturated with water, and an air/refrigerant fluid exchanger embedded in an insulated thermal mass, as well as an integrated separator, the compressed air is cooled to a pressure dew point of +3°C.

Our range of dryers allows the achievement of air quality in accordance with the ISO8573.1-2010 standard, humidity class 3 for flow rates ranging from 18 m3/h to3 160 m3/h.

Domaines d'application

Automobile
Chimie
Laser
Machine-outils
Nucléaire/Pétrolier
Outils pneumatiques
Pharmaceutique
Plasturgie
Scierie
Traitement de surface
Vinicole/Brassicole

Caractéristiques techniques

Réfrigérant R134a Réfrigérant R407c Froid Circuit frigorifique 1 Utilisation Intérieure Compresseur scroll Échangeur multitubulaire Ventilateur hélicoïde

Thermal mass heat exchanger

This patented heat exchanger, the result of CTA research and development, offers great energy savings thanks to its pre-exchanger/saver (from MPE-N 010), its low pressure drop and its high-performance separator. Its DTM technology ensures that the compressed air is not polluted by the refrigerant and guarantees dry, high-quality compressed air in all circumstances.

Refrigeration circuit

It includes all the safety features as standard in order to prevent faults from being generated by misuse. The purpose of these devices is to protect the refrigeration air dryer, but above all to ensure that it functions properly and that the user's process is maintained.

Compressor

Hermetic refrigeration compressors (piston, rotary, scroll) that provide adequate cooling to maintain the dew point under all conditions of use

Controller

The controller is standard on the first models and is designed to optimise the operation of the dryer with a dew point display, condensate drain control and correct operation of the refrigeration circuit. In addition, it allows the reporting of all alarms and malfunctions on the dryer as well as the reminder of maintenance deadlines.

Plug and Play product

Ready to use thermal mass refrigeration dryer with all components directly integrated and allowing easy operation. Masteria dryers are supplied with a power cable, which allows commissioning without having to open the dryer.

Low energy costs

High performance design through its 3-in-1 exchanger which ensures an extremely low pressure drop of 0.15 bar at the expressed nominal flow rate. When the dryer is in partial load, the refrigerant within the exchanger gives up the unused cold to the dry thermal mass that occupies the gaps between the fins and the heat exchanger tubes. The cold is then returned as required to the copper pipes through which the compressed air flows. The refrigeration compressor and fan can therefore be left idle for a long time to save energy. Take advantage of our energy saving calculation tool to find out the energy benefit of your system. Click here.

Simplified maintenance

Easy access from the top and side panels of the unit allows optimum maintenance of the dryer. The refrigeration design of Masteria dryers ensures direct access to all components. Technical diagnosis is facilitated by the presence of pressure taps within the refrigeration circuit, as well as the presence of a low pressure gauge on the front panel.

Guaranteed performance

Manufactured and tested in our factories and meeting the ISO8573.1-2010 standard, class 4 humidity, our dryers allow for optimal use over time. The digital controller, guaranteeing correct use and an accurate pressure dew point, ensures that the process downstream of the dryer is protected.

Optimised air circulation

The fan mounted directly in its own housing on the condenser allows for optimum efficiency of the available cooling capacity even at high ambient temperatures.

Record durability and high strength

Its reinforced body, painted in baked epoxy, ensures a long life even in the most corrosive and dusty environments. Its high efficiency condenser, equipped with robust fins, swept by the air without any obstacle allows the possibility of a cleaning and a great behaviour in time.

Models004006008010015020025030040050060075100125150200250300350400
Air flow[m3/h]304870100140175210260300420540660780920102013801800216025803160
Air flow[scfm]18284159821031241531772473183884595416008121059127115181860
Connections['']3/4"3/4"3/4"1"1"1"1-1/2"1-1/2"1-1/2"2"2"2"2-1/2"2-1/2"3"3"3"3"DN100DN100
Width[mm]4304654655755755757407407407407407407407407407401110111011101110
Lenght[mm]40646546554054054061861861876076076010741074155015501425142518751875
Height[mm]56565565576776776792692692698298298212021202150015001500150015001500
Weight[kg]425656868992125129133169174179245251365370430450510525
Electrical power[kW] 0,210,270,280,630,660,680,981,021,051,321,371,411,932,012,382,483,763,924,634,77
Power supply[V/P/F] 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 400/3/50 400/3/50 400/3/50 400/3/50
Number of circuits[n°]11111111111111111111
Refrigerant[HFC] R134a R134a R134a R407cR407cR407cR407cR407cR407cR407cR407cR407cR407cR407cR407cR407cR407cR407cR407cR407c