Pompe à chaleur à condensation par air - HERA - R290 | CTA

Cooling process

Because there is nothing more precious than your processes, for 30 years we have developed refrigeration systems combining modularity and reliability for the preservation and optimization of your production tools.

Air-cooled heat pump – HERA – R290 Semi-hermetic compression

35 Kw  > 195 Kw
Air-cooled heat pump – HERA – R290 Semi-hermetic compression

In a market seeking energy efficiency, easy-to-implement plug-and-play solutions, and a limited ecological footprint, the Hera air-cooled heat pump provides a complete and unique response to these demands.

At the heart of the "Natural Cooling" program and aligned with the values of the e3 label, this new generation of heat pumps meets the needs of the most demanding users and offers a sustainable solution for the future through the use of the natural refrigerant R290.

DOMAINES D'APPLICATION

Agri-food
Automobile
Chemistry
Laser
Machine tools
Nuclear/Oil
Pneumatic tools
Stationery
Pharmaceutical
Plastics industry
Sawmill
Surface finishing
Wine/Brewery

CARACTÉRISTIQUES PRINCIPALES

Refrigerant R290 Cold/Hot Semi-hermetic compressor Plate heat exchanger Propeller fan

Fans

The new technology of fans allows for optimized airflow exchange, high performance, and reduced noise levels. The electronically commutated (EC) motors also enable operation at very low temperatures (down to -20°C).

Structure

By achieving efficient cooling, the structure facilitates and secures maintenance operations. It offers excellent durability and protects electrical components through its built-in water retention basin.

Controller and Regulator

The "CTApps" application, designed for the Hera range, provides easy access to various system parameters while safeguarding the unit (user access, maintenance access, manufacturer access).

Compressors

Maintaining stable and consistent temperatures, the semi-hermetic piston compressors from Frascold offer energy-efficient performance, excellent efficiency, and outstanding reliability across all industrial and commercial applications.

Artificial Intelligence

The dynamic and rapid defrosting system continuously optimizes defrosting management through its artificial intelligence, achieving maximum efficiency. It adjusts in response to changes in environmental conditions.

Environmental Respect

The Hera line is 700 times less polluting than conventional heat pumps (HFC R410a), utilizing the natural refrigerant R290. It addresses key challenges through its high energy efficiency (SCOP, COP, EER, ESEER) and limited ecological footprint (GWP = 3). The HC R290 gas offers a sustainable and durable solution that fully complies with the F-Gas Regulation 517/2014.

Adaptability

The Hera is designed to adapt to the most hostile conditions, including corrosive and dusty environments, thanks to its extended operating range, special coil coatings, and reinforced electrical protections.

Modularity

Hera units offer an infinite array of options and configurations (over 5,000 different configurations) to suit each of your processes. Your installation is valuable and unique, making our response fully tailored to your needs.

Safety

Equipped with numerous mechanical and refrigeration safety features, the Hera range provides permanent and precise operational monitoring at every moment of use. Standard on all models is the latest c.Pco Carel system, compatible with various market supervisory protocols.

Energy Efficiency

Thanks to its semi-hermetic compressors optimized for these applications, the Hera offers unmatched energy efficiency for heating and cooling applications, as well as for the most demanding industrial processes.

Performances
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
Heating capacity35,753,867,483,294,5113,6135,9166,8188,9
Total power consumption[KW]10,916,421,125,129,235,541,349,858,7
COP[-]3,283,283,193,323,233,203,293,353,22
Water flow rate[m3/h]6,19,311,614,316,319,523,428,732,5
Pressure loss - version base [kPa]293451323440343743
Cooling capacity[kW]29,946,357,871,882,096,4117,5143,9164,4
Total power consumption[kW]11,916,922,926,331,837,245,952,863,7
EER[-]2,522,742,532,732,582,592,562,732,58
Water flow rate[m3/h]5,18,09,912,314,116,620,224,828,3
Pressure loss - basic version[kPa]263340262832333636
Refrigerant charge[kg]4,05,65,88,58,75,5x25,8x28,5x28,7x2
Number of refrigeration circuits111112222
Type of fans/quantities-1/Axial EC2/Axial EC2/Axial EC3/Axial EC3/Axial EC4/Axial EC4/Axial EC6/Axial EC6/Axial EC
Fan power consumption[kW]0,741,551,552,352,353,103,104,704,70
Total air flow[m3/h]13 90026 50026 50039 50039 50053 00053 00079 00079 000
Performance in average weather conditions in line with EU standard no. 813/2013 - Pdesign ≤ 400kW
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
SCOP[W/W]3,593,403,503,513,413,223,413,253,20
Ƞsh[%]140,5133,1137,2137,2133,5125,7133,4127,2125,1
Energy efficiency in accordance with standard no. 811/2013 - Heat pumps ≤ 70 kW
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
Seasonal energy efficiency classA++A++A++------
Electrical data
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
Main power supply400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Gas detector power supply refrigerant230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50
Max. absorbed current[kW]12,920,222,528,731,140,445,057,362,1
Locked rotor current LRA[A]<10<10<10<10<10<50<50<60<60
Maximum absorbed current FLA[A]22,339,740,749,752,779,481,499,4105,4
Integrated solution with hydraulic kit
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
Tank capacity[L]300300300300300470470470470
Pump typeCentrifugal(tous modèles)
Standard pump (1,5bar)
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
Electric motor efficiency classIE3IE3IE3IE3IE3IE3IE3IE3IE3
Nominal power input pump[kW]0,551,11,11,51,51,51,52,22,2
Nominal absorbed pump current[A]1,853,33,33,83,83,83,84,74,7
Oversized pump (3,0bar)
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
Electric motor efficiency classIE3IE3IE3IE3IE3IE3IE3IE3IE3
Nominal power input pump[kW]1,52,22,23,03,04,04,04,04,0
Nominal current absorbed by the pump[A]4,14,74,76,46,48,78,78,78,7
Hydraulic connections
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
Nominal outside diameter[inch]1"1"1/41"1/41"1/21"1/22"2"2"1/22"1/2
Noise levels
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
Acoustic power level (ver. ST)[db(A)]767979828582828586
Sound pressure level (ST) à 1m[db(A)]586161636663636566
Sound pressure level (ST) à 10m[db(A)]434747495250505253
Acoustic power level (ver. LN)[db(A)]757878818381818484
Acoustic power level (LN) à 1m[db(A)]576060626462626464
Acoustic power level (LN) à 10m[db(A)]424646485049495151
Acoustic power level (ver. SL)[db(A)]737777798080808282
Acoustic power level (SL) à 1m[db(A)]545757596160606161
Acoustic power level (SL) à 10m[db(A)]404343454746464848
Dimensions and weight
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
Length[mm]1 7752 3652 3653 3253 3253 2903 2904 0904 090
Width[mm]1 0501 0501 0501 0501 0502 1002 1002 1002 100
Height[mm]1 9001 9001 9001 9001 9001 9001 9001 9001 900
Shipping weight - ST version[kg]6504805407107201 0301 1501 5101 530
Operating weight - LN version[kg]3604955607307401 0601 1901 5601 580
Operating weight - SL version[kg]4406006808909001 2901 4401 8901 920
Dimensions with hydraulic kit
Models35-1-155-1-165-1-180-1-198-1-1110-2-2130-2-2160-2-2190-2-2
Length[mm]8008008008008001 1901 3301 7401 760
Width[mm]1 0501 0501 0501 0501 0501 2201 3701 8001 820
Height[mm]1 9001 9001 9001 9001 9001 4901 6602 1802 220
Operating weight - I/ST[kg]-----1 6901 8302 2402 260
Operating weight - I/LN[kg]-----1 7201 8702 3002 320
Operating weight - I/SL[kg]-----1 9902 1602 6802 720