Because there is nothing more precious than your processes, for 30 years we have developed refrigeration systems combining modularity and reliability for the preservation and optimization of your production tools.
For 20 years, the IPE with R410a has been a leading reference in the industrial cooling sector, specifically designed and developed to provide a bespoke solution for cooling capacities ranging from 11 to 371 kW. Technology, modularity, and reliability are at the core of this new series, which is 100% industry-focused.
These plug-and-play chilled water production units are compact and fully equipped to meet the demands of the most rigorous user processes, notably enhanced by its patented submerged evaporator, making the IPE series the most reliable and safest solution on the market.
Available in multiple versions and offering limitless configurations, the IPE R410a is your new ally and key asset for all small to medium-sized industrial applications.
Chassis
Specifically designed for outdoor installation, the chassis is constructed from galvanized cast steel. It features a powder polyester coating (RAL7035), with other colors available upon request, ensuring exceptional durability over time, including resistance to harsh weather conditions.
Compressor
The latest generation of hermetic Scroll compressors with orbiting spirals is specially designed for use with the R407c refrigerant.
Evaporator
The "No Frost" heat exchanger is submerged in a buffer tank and paired with a standard water pressure pump rated at 3.0 bar. This evaporator provides high thermal exchange efficiency and ensures optimal protection against freezing. It is equipped with a differential pressure switch to stop the unit in case of low water flow. The evaporator is hermetically insulated to prevent condensation issues.
Fans & Condensers
Premium helical fans feature sickle-shaped blades and high-efficiency motors. Their aerodynamic design minimizes pressure loss, enhancing efficiency. With IP54 protection, the state-of-the-art copper/aluminum coil ensures excellent thermal performance and improved energy efficiency. Mounted vertically and protected by a panel, these condensers are less exposed to damage and impacts.
Safety & Durability
The IPE is equipped with numerous mechanical and refrigeration safety features. It also features continuous operational monitoring through its state-of-the-art microprocessor, ensuring precise control at all times during use. This provides the IPE with an unmatched level of safety and 100% water distribution tailored to your process needs. Standard on all models is the latest μChiller Carel, compatible with various supervisory protocols. Additionally, advanced unit control is available through the c.Pco controllers and the "CTApps" application, optimizing unit performance.
Plug and Play
The IPE air-cooled Scroll chiller range includes a hydraulic module with a pressure transducer, allowing for water flow display and enhancing pump protection against low pressure. With numerous accessories included, it offers a straightforward Plug and Play solution for all users.
Modularity
The IPE units offer extensive modularity, featuring an infinite array of options and configurations (over 5,000 different configurations) to adapt seamlessly to each of your processes. Your installation is valuable and unique, and our solutions are fully tailored to meet your specific needs.
PERFORMANCES | ||||||||||||||||||||
Models | 21 | 31 | 51 | 81 | 101 | 121 | 151 | 201 | 251 | 301 | 351 | 401 | 502 | 602 | 702 | 802 | 1002 | 1202 | 1402 | |
Nominal cooling capacity(1) | [kW] | 11,1 | 14,9 | 20,7 | 27,9 | 32,4 | 37,2 | 40,5 | 54,1 | 64,0 | 81,2 | 94,9 | 113,0 | 126,0 | 147,0 | 181,0 | 231,0 | 289,0 | 342,0 | 371,0 |
Power consumption(1) | [kW] | 2,6 | 3,3 | 4,7 | 6,1 | 7,3 | 7,6 | 8,7 | 12,2 | 14,8 | 18,2 | 21,7 | 26,6 | 29,0 | 34,3 | 40,8 | 50,2 | 61,0 | 69,4 | 78,4 |
EER (1) | 4,3 | 4,6 | 4,4 | 4,6 | 4,5 | 4,9 | 4,7 | 4,4 | 4,3 | 4,5 | 4,4 | 4,2 | 4,3 | 4,3 | 4,4 | 4,6 | 4,7 | 4,9 | 4,7 | |
Nominal cooling capacity (2) | [kW] | 7,9 | 10,6 | 14,9 | 20,3 | 23,3 | 27,1 | 29,6 | 39,4 | 46,5 | 59,1 | 68,8 | 82,2 | 91,4 | 107,0 | 132,0 | 168,0 | 212,0 | 249,0 | 272,0 |
Power consumption (2) | [kW] | 3,0 | 3,7 | 5,2 | 6,8 | 8,0 | 8,2 | 9,3 | 13,1 | 16,0 | 19,7 | 23,6 | 28,4 | 31,4 | 37,3 | 44,4 | 53,9 | 66,4 | 76,5 | 86,4 |
EER (2) | 2,7 | 2,9 | 2,9 | 3,0 | 2,9 | 3,3 | 3,2 | 3,0 | 2,9 | 3,0 | 2,9 | 2,9 | 2,9 | 2,9 | 3,0 | 3,1 | 3,2 | 3,3 | 3,2 | |
SEPR | 4,51 | 4,55 | 4,57 | 4,53 | 4,51 | 4,62 | 4,60 | 4,95 | 4,94 | 4,76 | 4,92 | 5,37 | 5,60 | 5,41 | 5,45 | 5,38 | 5,63 | 5,58 | 5,47 | |
Eurovent Classification | D | C | C | B | C | B | B | B | B | B | B | A | A | A | A | B | A | A | A | |
REFRIGERATION CIRCUIT | ||||||||||||||||||||
Models | 21 | 31 | 51 | 81 | 101 | 121 | 151 | 201 | 251 | 301 | 351 | 401 | 502 | 602 | 702 | 802 | 1002 | 1202 | 1402 | |
Refrigerant - HFC | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | |
GWP | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | 2088 | |
Refrigerant charge | [Kg] | 1,7 | 2,3 | 2,7 | 4 | 4,2 | 5 | 5,5 | 7 | 7,6 | 10 | 10,5 | 11 | 17 | 19 | 21 | 30 | 40 | 54 | 58 |
CO2 equivalence | [tCO2] | 3,5 | 4,8 | 5,6 | 8,4 | 8,8 | 10,4 | 11,5 | 14,6 | 15,9 | 20,9 | 21,9 | 23,0 | 35,5 | 39,7 | 43,8 | 62,6 | 83,5 | 112,8 | 121,1 |
Nombre de circuits | [nø] | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Type of compressors | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | |
Number of compressors | [nø] | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 4 | 4 | 4 | 4 |
Fan type | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | |
Number of fans | [nø] | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 4 | 4 | 6 | 6 |
Air flow - fans | [m3/h] | 3450 | 6100 | 6100 | 11900 | 11900 | 11350 | 11350 | 22800 | 22800 | 28400 | 37600 | 35300 | 37500 | 55500 | 51900 | 82600 | 79800 | 125400 | 125400 |
Fluid flow - evaporator (1) | [m3/h] | 1,9 | 2,6 | 3,6 | 4,8 | 5,6 | 6,4 | 7,0 | 9,3 | 11,0 | 14,0 | 16,4 | 19,5 | 21,7 | 25,3 | 31,2 | 39,8 | 49,8 | 59,0 | 64,0 |
HYDRAULIC KIT | ||||||||||||||||||||
Models | 21 | 31 | 51 | 81 | 101 | 121 | 151 | 201 | 251 | 301 | 351 | 401 | 502 | 602 | 702 | 802 | 1002 | 1202 | 1402 | |
Buffer tank capacity | [L] | 30 | 60 | 60 | 160 | 160 | 160 | 160 | 290 | 290 | 460 | 460 | 460 | 500 | 500 | 500 | 920 | 920 | 1000 | 1000 |
Pump type | Peripheral | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | Centrifuge | |
Available pump pressure - P3 | [bar] | 4,16 / 2,10 | 2,71 / 2,38 | 2,60 / 2,15 | 2,88 / 2,53 | 3,05 / 2,94 | 3,05 / 2,84 | 3,05 / 2,81 | 3,01 / 2,55 | 3,61 / 2,95 | 3,45 / 2,70 | 2,88 / 2,67 | 2,88 / 2,58 | 2,88 / 2,58 | 3,60 / 3,16 | 3,51 / 2,90 | 3,15 / 2,76 | 3,15 / 2,50 | 3,66 / 2,81 | 3,61 / 2,63 |
Available pump pressure - P5 | [bar] | 7,28 / 5,04 | 6,70 / 3,54 | 5,61 / 3,24 | 6,03 / 4,56 | 5,88 / 4,14 | 6,52 / 5,68 | 6,74 / 5,54 | 6,24 / 4,05 | 6,03 / 3,19 | 5,07 / 4,37 | 4,41 / 4,16 | 4,41 / 4,07 | 5,26 / 4,90 | 5,22 / 4,80 | 5,13 / 4,52 | 5,44 / 5,01 | 5,44 / 4,72 | 5,38 / 4,34 | 5,32 / 4,14 |
Connection diameter | [''] | 1/2'' (DN15) | 1'' (DN25) | 1'' (DN25) | 1''1/4 (DN32) | 1''1/4 (DN32) | 1''1/4 (DN32) | 1''1/4 (DN32) | 1''1/2 (DN40) | 1''1/2 (DN40) | 2'' (DN50) | 2'' (DN50) | 2'' (DN50) | 3'' (DN80) | 3'' (DN80) | 3'' (DN80) | 3'' (DN80) | 3'' (DN80) | 3'' (DN80) | 4'' (DN100) |
ELECTRICAL DATA | ||||||||||||||||||||
Models | 21 | 31 | 51 | 81 | 101 | 121 | 151 | 201 | 251 | 301 | 351 | 401 | 502 | 602 | 702 | 802 | 1002 | 1202 | 1402 | |
Power supply | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | |
Total power input excluding pump | [kW] | 4,7 | 5,5 | 7,7 | 10,1 | 11,6 | 13,3 | 14,5 | 18,4 | 23,3 | 29,9 | 32,8 | 37,5 | 40,3 | 47,9 | 59,7 | 74,4 | 92,0 | 106,7 | 118,3 |
Locked rotor current - LRA - hors pompe | [A] | 48,5 | 66,9 | 73,9 | 101,6 | 101,6 | 101,7 | 101,7 | 162,3 | 129,0 | 136,0 | 163,3 | 207,6 | 279,6 | 290,4 | 347,7 | 296,2 | 370,2 | 434,3 | 455,1 |
Maximum absorbed current | [A] | 11,3 | 13,3 | 18,3 | 24,2 | 27,3 | 30,8 | 33,2 | 44,2 | 54,7 | 67,5 | 79,1 | 89,5 | 77 | 87,8 | 108,8 | 178,1 | 167,6 | 195,4 | 216,2 |
Fan power consumption (1) | [kW] | 0,2 | 0,4 | 0,4 | 0,7 | 0,7 | 0,7 | 0,7 | 1,5 | 1,5 | 2,3 | 3,5 | 3,6 | 2 | 5,3 | 5,5 | 6,6 | 6,8 | 9,9 | 9,9 |
Pump power consumption (1)(3) | [kW] | 0,6 | 0,55 | 0,55 | 0,9 | 1,5 | 1,5 | 1,5 | 1,5 | 1,8 | 1,8 | 3 | 3 | 3 | 4 | 4 | 5,5 | 5,5 | 7,5 | 7,5 |
Pump power consumption (1)(4) | [kW] | 1,1 | 1,1 | 0,9 | 1,3 | 1,3 | 2,2 | 2,2 | 2,2 | 2,2 | 4 | 5,5 | 5,5 | 7,5 | 7,5 | 7,5 | 11 | 11 | 11 | 11 |
NOISE LEVELS (5) | ||||||||||||||||||||
Models | 21 | 31 | 51 | 81 | 101 | 121 | 151 | 201 | 251 | 301 | 351 | 401 | 502 | 602 | 702 | 802 | 1002 | 1202 | 1402 | |
Power levels (ST version) | [dB(A)] | 93 | 85 | 85 | 84 | 85 | 86 | 86 | 85 | 85 | 85 | 93 | 93 | 92 | 93 | 94 | 95 | 95 | 95 | 95 |
Pres. levels (ST version) - at 1 metre | [dB(A)] | 77 | 69 | 69 | 67 | 69 | 69 | 69 | 68 | 68 | 67 | 75 | 75 | 73 | 74 | 75 | 75 | 76 | 75 | 75 |
Pres. levels (ST version) - at 10 metres | [dB(A)] | 61 | 54 | 54 | 52 | 54 | 55 | 55 | 53 | 53 | 53 | 61 | 61 | 60 | 61 | 62 | 62 | 63 | 63 | 63 |
Power levels (LN version) | [dB(A)] | 90 | 82 | 82 | 81 | 82 | 83 | 83 | 82 | 82 | 82 | 90 | 90 | 89 | 90 | 91 | 92 | 92 | 92 | 92 |
Pres. levels (LN version) - at 1 metre | [dB(A)] | 74 | 66 | 66 | 64 | 66 | 66 | 66 | 65 | 65 | 64 | 72 | 72 | 70 | 71 | 72 | 72 | 73 | 72 | 72 |
Pres. levels (LN version) - at 10 metres | [dB(A)] | 58 | 51 | 51 | 49 | 51 | 52 | 52 | 50 | 50 | 50 | 58 | 58 | 57 | 58 | 59 | 59 | 60 | 60 | 60 |
DIMENSIONS AND WEIGHT | ||||||||||||||||||||
Models | 21 | 31 | 51 | 81 | 101 | 121 | 151 | 201 | 251 | 301 | 351 | 401 | 502 | 602 | 702 | 802 | 1002 | 1202 | 1402 | |
Length | [mm] | 830 | 980 | 980 | 1280 | 1280 | 1280 | 1280 | 1930 | 1930 | 2580 | 2580 | 2580 | 3520 | 3520 | 3520 | 3900 | 3900 | 5000 | 5000 |
Width | [mm] | 645 | 795 | 795 | 990 | 990 | 990 | 990 | 990 | 990 | 990 | 990 | 990 | 990 | 990 | 990 | 2000 | 2000 | 2000 | 2000 |
Height | [mm] | 1405 | 1820 | 1820 | 2090 | 2090 | 2090 | 2090 | 2190 | 2190 | 2268 | 2268 | 2268 | 2250 | 2328 | 2328 | 1946 | 1946 | 2245 | 2245 |
Shipping weight | [Kg] | 200 | 265 | 275 | 460 | 480 | 485 | 495 | 660 | 750 | 995 | 1100 | 1120 | 1320 | 1380 | 1400 | 2280 | 2300 | 2590 | 2700 |
Operating weight | [Kg] | 230 | 325 | 335 | 620 | 640 | 645 | 655 | 950 | 1040 | 1455 | 1560 | 1580 | 1820 | 1880 | 1900 | 3200 | 3220 | 3590 | 3700 |